Informations techniques
| Device application : | Distribution |
|---|---|
| Range : | Acti 9 |
| Range of product : | IC60 |
| Product name : | Acti 9 iC60 |
| Product or component type : | Miniature circuit-breaker |
| Device short name : | IC60L |
| Poles description : | 3P |
| Number of protected poles : | 3 |
| [In] rated current : | 4 A |
| Network type : | DCAC |
| Trip unit technology : | Thermal-magnetic |
| Curve code : | Z |
| Breaking capacity code : | L |
| Breaking capacity : | 15000 A Icn at 400 V AC 50/60 Hz conforming to EN/IEC 60898-170 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2100 kA Icu at 12...60 V AC 50/60 Hz conforming to EN/IEC 60947-2100 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2100 kA Icu at 100...133 V AC 50/60 Hz conforming to EN/IEC 60947-2100 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-220 kA Icu at |
| Utilisation category : | Category A conforming to EN 60947-2Category A conforming to IEC 60947-2 |
| Suitability for isolation : | Yes conforming to EN 60947-2Yes conforming to IEC 60947-2 |
| Standards : | IEC 60947-2EN 60947-2 |
| Network frequency : | 50/60 Hz |
|---|---|
| [Ue] rated operational voltage : | 220...240 V AC 50/60 Hz380...415 V AC 50/60 Hz440 V AC 50/60 Hz12...133 V AC 50/60 Hz125...180 V DC |
| Magnetic tripping limit : | 3 x In +/- 20 % |
| [Ics] rated service breaking capacity : | 100 kA 100 % conforming to EN 60947-2 - 220...240 V AC 50/60 Hz100 kA 100 % conforming to IEC 60947-2 - 220...240 V AC 50/60 Hz100 kA 100 % conforming to EN 60947-2 - 380...415 V AC 50/60 Hz70 kA 100 % conforming to EN 60947-2 - 440 V AC 50/60 Hz100 kA 100 % conforming to IEC 60947-2 - 380...415 V AC 50/60 Hz70 kA 100 % conforming to IEC 60947-2 - 440 V AC 50/60 Hz100 kA 100 % conforming to EN 60947-2 - 12...133 V AC 50/60 Hz100 kA 100 % conforming to IEC 60947-2 - 12...133 V AC 50/60 Hz20 kA 100 % conforming to EN 60947-2 - 125...180 V DC20 kA 100 % conforming to IEC 60947-2 - 125...180 V DC |
| Limitation class : | 3 conforming to EN 60898-13 conforming to IEC 60898-1 |
| [Ui] rated insulation voltage : | 500 V AC 50/60 Hz conforming to EN 60947-2500 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage : | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
| Contact position indicator : | Yes |
| Control type : | Toggle |
| Local signalling : | Trip indicator |
| Mounting mode : | Fixed |
| Mounting support : | DIN rail |
| Comb busbar and distribution block compatibility : | Top or bottom: YES |
| 9 mm pitches : | 6 |
| Height : | 85 mm |
| Width : | 54 mm |
| Depth : | 78.5 mm |
| Product weight : | 0.375 kg |
| Colour : | White |
| Mechanical durability : | 20000 cycles |
| Electrical durability : | 10000 cycles |
| Connections - terminals : | Single terminal (top or bottom) 1...25 mm² rigidSingle terminal (top or bottom) 1...16 mm² flexible |
| Wire stripping length : | 14 mm for top or bottom connection |
| Tightening torque : | 2 N.m top or bottom |
| Earth-leakage protection : | Separate block |
| Compatibility code : | IC60 |