calcActive())">
SCHNEIDER
STRAIGHT LENGTH100 A - KNA100ED4306
KNA100ED4306
On quote only, please contact the sales department for an estimate.
Technical informations
| Range: | Canalis |
|---|---|
| Range of product: | Canalis |
| Product name: | KN |
| Product or component type: | Busbar trunking |
| Busbar description: | Distribution length |
| Device short name: | KNA |
| Device application: | Low power distribution |
| [Ie] rated operational current: | 100 A at 35 °C |
| Busbar trunking polarity: | 3L + PEN3L + N + PE |
| Number of tap-off outlets: | 6 |
| Length: | 3 m |
| [Ue] rated operational voltage: | 230...500 V |
|---|---|
| Network frequency: | 50/60 Hz |
| [Uimp] rated impulse withstand voltage: | 6 kV |
| [Ui] rated insulation voltage: | 500 V |
| [Icw] rated short-time withstand current: | 2.8 kA |
| [Ipk] rated peak withstand current: | 14 kA |
| Electrical connection: | Lubricated sliding contact |
| Radiated magnetic field: | 0.106 µT |
| Thermal stress limit: | 8000 kA².s |
| THDI: | 0...15 % 100 A15...33 % 80 A33...100 % 63 A |
| Maximum voltage drop: | |
| Linear resistance: | 0.85 m?/m R20 20 °C phase conductor1.02 m?/m R1 35 °C at Inc and 50 Hz phase conductor0.25 m?/m X1 35 °C at Inc and 50 Hz phase conductor1.05 m?/m Z1 35 °C at Inc and 50 Hz phase conductor1.09 m?/m 20 °C protective conductor3.72 m?/m R0 20 °C symmetrical components method Ph/N1.56 m?/m X0 20 °C symmetrical components method Ph/N4.03 m?/m Z0 20 °C symmetrical components method Ph/N3.84 m?/m R0 20 °C symmetrical components method Ph/PE1.66 m?/m X0 20 °C symmetrical components method Ph/PE4.18 m?/m Z0 20 °C symmetrical components method Ph/PE1.71 m?/m Rb0 20 °C impedance method Ph/PE1.73 m?/m Rb0 20 °C impedance method Ph/N2.03 m?/m Rb0 20 °C impedance method Ph/PE2.05 m?/m Rb1 35 °C at Inc with impedance method Ph/Ph2.07 m?/m Rb1 35 °C at Inc with impedance method Ph/N2.43 m?/m Rb1 35 °C at Inc with impedance method Ph/PE0.52 m?/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/Ph0.78 m?/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/N0.96 m?/m Xb 35 °C at Inc and 50 Hz with impedance method Ph/PE |
| Mounting mode: | By screws |
| Neutral position: | Up |
| Number of circuits: | 1 |
| Control type: | Without |
| Standards: | IEC 61439-6IEC 60439-2 |
| Width: | 92 mm |
| Depth: | 27.5 mm |
| Colour: | White (RAL 9001) |
| Product weight: | 7.3 kg |
In short
Reference
KNA100ED4306
Product Name
STRAIGHT LENGTH100 A - KNA100ED4306
Device function
Distribution de faible puissance
Related Categories