motor controller LTMR TeSys T - 24 V DC 8 A for CANopen - LTMR08CBD
LTMR08CBD
€536.13
Excl. Tax
€643.36
Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process - Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range: | TeSys |
|---|---|
| Product name: | TeSys T |
| Device short name: | LTMR |
| Product or component type: | Motor controller |
| Device application: | Equipment monitoring and control |
| Measurement current: | 0.4...8 A |
| [Us] rated supply voltage: | 24 V DC |
| Current consumption: | 56...127 mA |
| Supply voltage limits: | 20.4...26.24 V DC |
| Communication port protocol: | CANopen |
| Bus type: | CANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, SUB-D 9 with 4 twisted shielded pairs cableCANopen ISO 1198 interface, addressing 1...127, transmission rate 10...1000 kbit/s, terminal block with 4 twisted shielded pairs cable |
| [Ui] rated insulation voltage: | 690 V conforming to EN/IEC 60947-1690 V conforming to CSA C22.2 No 14690 V conforming to UL 508 |
|---|---|
| [Uimp] rated impulse withstand voltage: | 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-10.8 kV communication circuit conforming to EN/IEC 60947-4-10.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 |
| Short-circuit withstand: | 100 kA conforming to EN/IEC 60947-4-1 |
| Associated fuse rating: | 4 A gG for output0.5 A gG for control circuit |
| Protection type: | Overload (long time)Phase failureLoad fluctuationPhase imbalanceReverse polarity protectionThermal protectionThermal overload protectionEarth-leakage protectionPower factor variationOverloadLocked rotor |
| Network and machine diagnosis type: | Trip context informationRemaining operating time before overload trippingStarting current and timeEvent recordingMotor control command recordingRunning hours counter/operating timeWaiting time after overload trippingTrip history informationPhase fault and earth fault trip countersFault recording |
| Logic input number: | 6 |
| Input current: | 7 mA |
| Current state 0 guaranteed: | Logic input: |
| Current state 1 guaranteed: | Logic input: |
| Maximum operating frequency: | 2 Hz |
| Load current: | 5 A at 250 V AC for logic output5 A at 30 V DC for logic output |
| Permissible power: | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| Maximum operating rate: | 1800 cyc/h |
| Contacts type and composition: | 1 NO + 1 NC fault signal3 NO |
| Metering type: | Average current IavgPhase current I1, I2, I3 RMSTemperatureEarth-fault currentImbalance current |
| Measurement accuracy: | 5...15 % earth fault current internal measurement1 % voltage (100...830 V)3 % power factor5 % earth fault current external measurement+/- 30 min/year internal clock0,02 temperature1 % current5 % active and reactive power |
| Overvoltage category: | III |
| Connection pitch: | 5.08 mm |
| Connections - terminals: | Control circuit: connector 1 cable(s) 0.25...2.5 mm² (AWG 24...AWG 14) flexible with cable endControl circuit: connector 1 cable(s) 0.2...2.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 1 cable(s) 0.25...2.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 1 cable(s) 0.2...2.5 mm² (AWG 24...AWG 14) solid without cable endControl circuit: connector 2 cable(s) 0.2...1 mm² (AWG 24...AWG 14) flexible with cable endControl circuit: connector 2 cable(s) 0.2...1.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 2 cable(s) 0.5...1.5 mm² (AWG 24...AWG 14) flexible without cable endControl circuit: connector 2 cable(s) 0.2...1 mm² (AWG 24...AWG 14) solid without cable end |
| Tightening torque: | Control circuit: 0.5...0.6 N.m flat screwdriver 3 mm |
| Pollution degree: | 3 |
| Electromagnetic compatibility: | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 |
| Width: | 91 mm |
| Height: | 61 mm |
| Depth: | 122.5 mm |
| Product weight: | 0.53 kg |
| Web services: | Web server |
| Compatibility code: | LTMR |