Technical informations
| Range of product: | Modicon TM3 |
|---|---|
| Product or component type: | Analog input module |
| Range compatibility: | Modicon M221Modicon M241Modicon M251Modicon M262 |
| Analogue input number: | 4 |
| Analogue input type: | current 4...20 mA current 0...20 mA voltage 0...10 V voltage - 10...10 V thermocouple - 200...1000 °C with thermocouple J thermocouple - 200...1300 °C with thermocouple K thermocouple 0...1760 °C with thermocouple R thermocouple 0...1760 °C with thermocouple S thermocouple 0...1820 °C with thermocouple B thermocouple - 200...400 °C with thermocouple T thermocouple - 200...1300 °C with thermocouple N thermocouple - 200...800 °C with thermocouple E thermocouple 0...2315 °C with thermocouple CPt 100 temperature probe - 200...850 °CPt 1000 temperature probe - 200...600 °C |
| Analogue input resolution: | 16 bits15 bits + sign |
|---|---|
| Permissible continuous overload: | 13 V, analogue input type: voltage40 mA, analogue input type: current |
| Input impedance: | >= 1 MOhm voltage>= 1 MOhm thermocouple>= 1 MOhm temperature probe |
| LSB value: | 2.44 mV 0...10 Vvoltage4.88 mV - 10...10 Vvoltage4.88 µA 0...20 mAcurrent3.91 µA 4...20 mAcurrent0.1 °Ctemperature probe0.1 °Cthermocouple |
| Conversion time: | 100 ms + 100 ms per channel + 1 controller cycle time for analogue input thermocouple100 ms + 100 ms per channel + 1 controller cycle time for analogue input temperature probe10 ms + 10 ms per channel + 1 controller cycle time for analogue input voltage/current |
| Sampling duration: | 10 ms, analogue input type: voltage/current100 ms, analogue input type: voltage/current100 ms, analogue input type: thermocouple100 ms, analogue input type: temperature probe |
| Absolute accuracy error: | +/- 0.2 % of full scale at 25 °C for analogue input voltage/current+/- 0.2 % of full scale at 25 °C for Pt 100/Pt 1000, Ni 100/ Ni 1000 temperature probe+/- 0.2 % of full scale at 25 °C for thermocouple C 0...2315 °C+/- 6 °C at 25 °C for thermocouple R, S 0...200 °C+/- 0.2 % of full scale at 25 °C for thermocouple R, S 200...1760 °C+/- 0.2 % of full scale at 25 °C for thermocouple B 300...1820 °C+/- 0.4 % of full scale at 25 °C for thermocouple K - 200...0 °C+/- 0.2 % of full scale at 25 °C for thermocouple K 0...1300 °C+/- 0.4 % of full scale at 25 °C for thermocouple J - 200...0 °C+/- 0.2 % of full scale at 25 °C for thermocouple J 0...1000 °C+/- 0.4 % of full scale at 25 °C for thermocouple E - 200...0 °C+/- 0.2 % of full scale at 25 °C for thermocouple E 0...800 °C+/- 0.4 % of full scale at 25 °C for thermocouple T - 200...0 °C+/- 0.2 % of full scale at 25 °C for thermocouple T 0...400 °C+/- 0.4 % of full scale at 25 °C for thermocouple N - 200...0 °C+/- 0.2 % of full scale at 25 °C for thermocouple N 0...1300 °C |
| Temperature drift: | +/- 0.01 %FS/°C |
| Repeat accuracy: | +/-0.5 %FS |
| Non-linearity: | +/- 0.2 %FS |
| Cross talk: | |
| [Us] rated supply voltage: | 24 V DC |
| Supply voltage limits: | 20.4...28.8 V |
| Type of cable: | Twisted shielded pairs cable |
| Current consumption: | 45 mA at 5 V DC via bus connector50 mA at 5 V DC via bus connector35 mA at 24 V DC via external supply40 mA at 24 V DC via external supply |
| Local signalling: | 1 LED (green) for PWR |
| Electrical connection: | 10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs and supply10 x 1.5 mm² removable screw terminal block with pitch 3.81 mm adjustment for inputs |
| Insulation: | Between input and supply at 1500 V ACBetween input and internal logic at 500 V AC |
| Marking: | CE |
| Surge withstand: | 1 kV power supply common mode conforming to EN/IEC 61000-4-50.5 kV power supply differential mode conforming to EN/IEC 61000-4-51 kV input common mode conforming to EN/IEC 61000-4-5 |
| Mounting support: | Top hat type TH35-15 rail conforming to IEC 60715Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit |
| Height: | 90 mm |
| Depth: | 70 mm |
| Width: | 23.6 mm |
| Net weight: | 0.1 kg |