calcActive())">
SCHNEIDER
TeSys VccD - inter.-sectionneur - 3P - 690V 32A - poignée rouge cadenassable - VCCD1
VCCD1
€29.80
Excl. Tax
€35.76
Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
Supply in process - Average delivery time 4/6 weeks
- Technical support and dedicated single point of contact
- Free delivery from 250€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
| Range: | TeSys |
|---|---|
| Product name: | TeSys VARIO |
| Device short name: | VCCD |
| Product or component type: | Emergency stop switch disconnector |
| Performance level: | High performance |
| Poles description: | 3P |
| Contacts type and composition: | 3 NO |
| Network type: | ACDC |
| Control type: | Rotary handle |
| Rotary handle mounting style: | Extended |
| Handle colour: | Red |
| Handle front plate colour: | Yellow |
| Suitability for isolation: | Yes |
| Rotary handle padlocking: | 1 to 3 padlocks 4...8 mm |
|---|---|
| Marking: | 0 - 1 |
| Mounting support: | Handle mounting on doorSwitch mounting on symmetrical railSwitch mounting on plate |
| Fixing mode: | Hole with 22.5 mm for handleBy clips for switchBy screws for switch |
| [Ue] rated operational voltage: | 690 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage: | 8 kV |
| [Ith] conventional free air thermal current: | 32 A |
| [Ithe] conventional enclosed thermal current: | 25 A |
| [Ie] rated operational current: | 21.8 A (AC-23) at 400 V |
| Rated operational power in W: | 11 kW at 500 V (AC-23A)15 kW at 690 V (AC-23A)1.5 kW at 230...240 V (AC-3)7.5 kW at 500 V (AC-3)7.5 kW at 690 V (AC-3)5.5 kW at 230...240 V (AC-23A)11 kW at 400...415 V (AC-23A)7.5 kW at 400...415 V (AC-3) |
| Intermittent duty class: | 30 |
| Making capacity: | 320 A at 400 V (AC-21A)320 A at 400 V (AC-22A)320 A at 400 V (AC-23A) |
| [Icm] rated short-circuit making capacity: | 1 kA at 400 V at Ipeak |
| [Icw] rated short-time withstand current: | 384 A at 400 V during 1 s |
| Rated conditional short-circuit current: | 10 kA at 400 V - associated fuse 35 A aM10 kA at 400 V - associated fuse 35 A gG |
| Breaking capacity: | 250 A at 400 V AC-21A250 A at 400 V AC-22A250 A at 400 V AC-23A |
| Device composition: | HandleShaft extensionSwitch |
| Mechanical durability: | 100000 cycles |
| Electrical durability: | 30000 cycles DC-1...5100000 cycles AC-21 |
| Connections - terminals: | Power circuit |
| Tightening torque: | Power circuit |
| Base dimension: | 60 x 60 mm |
| Height: | 74 mm |
| Width: | 60 mm |
| Product weight: | 0.392 kg |
In short
Reference
VCCD1
Product Name
TeSys VccD - inter.-sectionneur - 3P - 690V 32A - poignée rouge cadenassable - VCCD1
Range
TeSys
Related Categories